E40C-1490-6 Dryzone baking dry cabinet

<5% RH fully automatic, H/T warming system, Calibration reminder, Antistatic finishing Black cabinet, Antistatic caster - details see: https://www.machineto.com/e40c-1490-6-dryzone-baking-dry-cabinet-10289665
Condition:NewType:Drying OvenPlace of Origin:Shanghai China (Mainland)Brand Name:Dryzone
Model Number:E40C-1490-6Voltage:110V/230VPower(W):Ave. 600Wh; Max. 1200WDimension(L*W*H):W1200*H1820*D695
Weight:146kgCertification:CE UL PPS ISO RoHsWarranty:1 yearAfter-sales Service Provided:Overseas service center available
E40C-1490-6 Dryzone baking dry cabinet
contact supplier for E40C-1490-6 Dryzone baking dry cabinet


E40C-1490-6 Baking 40°C auto dry cabinet

Specifications

TemperatureHumidity Range:40±2°C; <5%RH (auto)
External Dimension:W×H×D(mm):1200×1820×695
Internal Dimension:W×H×D(mm):1198×1618×645
Capacity:1250L
Shelves:5 shelves (stainless)
Color:black
Voltage:110V/230V
Display Precision Tolerance:±1°C, ±3%RH
Wheels:4 antistatic 3” wheels, 2 of them with brakes.
Grounding Wire:1MΩ. (940mm long)
ESD Paint:106~109Ω. (surface resistance)
Power Consumption:Ave. 600Wh; Max. 1200W

E40C is a bi-functional auto dry cabinet. Heaters and dehumidifiers work at the same time to increase the evaporation. Dehumidifying rate works 2 times faster than the regular dry cabinet. It bakes and stables the cabinet temperature at 40°C and 5%RH in constant. When the heating reach to 40°C, it switches its function to dehumidifying system and continues to work, keeping the humidity at ultra-low <5%RH, preventing moistures from re-entering the components It is especially designed to comply with J-STD-033 for all the moisture sensitive SMD storages.

4 major functions:
According to J-STD-033B that Moisture sensitivity SMD packages which are exposed to the air and exceed the floor life should be baked at 40°C and stored in <5%RH ambient to reset their floor life (see J-STD-033B table 4-1, 4-3).

Our E40C is especially designed to fit for this requirement.

Wider application in resetting the floor life: For example: If MSD parts Level 4,5 and 5a are exposed to the air for less than 8 hours, they should be stored in a dry cabinet to reset their floor life. However, if their exposure time is longer than 8 hours, the SMD packages must store at 40°C baking machine to reset the floor life to zero.
Labor saving: SMD packages shipped in low temperature is suggested not to bake in a traditional temperature oven higher than 40°C, as it is very likely to cause deformation to the components. Parts storing in our T40C, operators do not need to remove the SMD package to thermally safer carriers. It is hassle free for move & removing to save labor cost; on top of that it eliminates the chance of damaging the carriers during removing.
H/T warming system: When the temperate or Humidity is exceeded the pre-set allow value, the warming alarm buzzed to alert the users taking further action to protect the storages.

Our factory

Factory: KUNSHAN GAOQIANG INDUSTRIAL EQUIPMENT CO., LTD
No. 2898 Beimen Rd., Hi-Tech Industrial Park, Kunshan, Jiansu, China

Some of our parterners:

and so on.

The authentication

CED\CE\UL\ISO9001:2000\EMC\RoSH and so on

CE approved with antistatic finishing paint on the cabinets together with antistatic wheels protects the box and shelves better from any possible static induction and it is hassle free for cabinet movement.

Our PPS dehumidifier Turbo dryer box is heat resistible to 230°C, The structure will not deform in high temperature, providing better safety for users and items in storage.

Delivery process

About Us

With 20 years of experiences inHumidity Control Solutionand subsidize by Dr. Storage in Taiwan, Dryzone desiccators is especially designed and made to comply with J-STD-033/IPC. They are suit for industrial and home user to tackle for humidity problems and it has been widely used all over the world.

Manufactured with the strictest attitude and comply with ISO9001 standard. Each and every Dryzone desiccant cabinet is of the highest quality and the best performance in the industry. Our RD is dedicate to provide the best and the most convenient storage solution for all humidity problems. Not only do we focus on the performance of our products, we also incorporate Environmental Friendly design to all of our drying boxes and have helped out many reputable SMT / IT customers cutting their product defective rate to zero, and substantially saving them worth of hundred and thousands US dollars each year.

Understand Moisture Damages

Moisture damage is everywhere and it causes inconvenience to our daily life. When humidity is over 60%RH in the air, molding, rusting or even corrosion and oxidation appears to a certain extent on some Moisture Sensitively objects.

What is relative humidity? Relative humidity is the amount of water vapors in the air at certain temperature compare to the maximum amount of water can hold without condensing.

To protect your valuable possessions from moisture damages, relative humidity should be carefully controlled when storing these materials. Without a proper control of relative humidity, moisture damages will not only damage your possessions but also affects your health.

It is strongly recommended to store your Moisture Sensitive materials in proper storage ambient

Moisture Sensitive MaterialsBest Storage Condition (%RH)
Cameras, Lens, Telescopes, Microscopes, Memory Cards, Films, Projector, Slides, Photographs, Documents, DVDs, Paintings, Antiques, Albums, Currency Collection, Optoelectronics Parts, Leather, Jewelry , etc.40~50%RH
Sensitive Electronic Instruments, Electronic Devices, Measuring Devices, Semiconductors, Capacitor, Battery, Sensors, Wafer, IC, PCB, etc.30~40%RH
Precious Machine, Medicine, Samples, Seeds, Pollen, Dried Flowers, Spices, Tea, Coffee, Snacks, Dried Food Products, etc.20~30%RH
Special Chemicals, Electronic Components, MSD, etc.1~15%RH


E40C-1490-6 Dryzone baking dry cabinet
Packaging Detail:Wooden case
Delivery Detail:Within1 to15 days after order confirmed

Related Product for E40C-1490-6 Dryzone baking dry cabinet