one host with many reacors ,integrated temperature control systems for 3-20 reactors.

1.single fluid circulation machine, 2.application:jacket reactor, 3.water or air -cooled, 4.material:SUS304 - details see: https://www.machineto.com/one-host-with-many-reacors-integrated-temperature-control-systems-for-3-20-reactors-10246228
Type:CompressorPlace of Origin:Jiangsu China (Mainland)Brand Name:LNEYAModel Number:SUNDI
Certification:CEAfter-sales Service Provided:Engineers available to service machinery overseasapplication:connect with jactor for pharmaceutical roductionmaterial:SUS 304
refrigeration machine:water or air cooledCOMPRESSOR:EMERSON /COPELAND/BOCK,BockEVAPORATOR:KAORI PLATE HEAT EXCHANGERprogram edit:20 programs
feedback:jacket oil   
one host with many reacors ,integrated temperature control systems for 3-20 reactors.
contact supplier for one host with many reacors ,integrated temperature control systems for 3-20 reactors.


Decription:
Two-level compressor single liquid temperature control system uses heat energy (steam,cooling water and ultra-low temperature liquid ---that is primary system) integrated into single liquid system or two-level return circuit to control the temperature of machine,that is only one heat oil flows into jacket of reactor. it controls the temperature by operation.
Features :
It is a closed system, operate the program repeatedly, temperature range is -120~300°C.
No need to change the heat oil;low capacity also can realize the fast reaction of control return circuit,shorten the time of delay of heat reaction.
Inbuilt air-heated heat oil assistant system,open assistant heating system,decrease steam usage pressure according the demands.
Fast running and accuracy matching of heat demands can get the purpose of saving energy.
Precisely control the reaction process temperature by accurate operation and make repaid reaction to endothermic and exothermic reaction.
Spare standard connection according to demands.
Options: control reaction process temperature or single liquid temperature ,moreover set the DELTA temperature.
Record of recipe management and production.

ModelSR-10SR-20SR-38SR-60SR-95
Operating temp range-120~200°C-120~200°C-120~200°C-120~220°C-120~220°C
Capacity of reactor50L~250L100L~500L300L~1000L500L~2000L1000L~5000L
Pump flow3m3/h

1.5bar

2.4~6.6m3/h

1.5bar

5~12m3/h

2.5bar

11~25m3/h

2.5bar

20~50m3/h

2.5bar

Pump controlSpeed regulation (NO)

Frequency conversion

Heating power10KW20KW38KW60KW95KW
ConnectionDN-25DN-25DN-40DN-65DN-80
Primary energy

electricity,steam,hot oil,hot water,cooling water,frozen water,ultra-low medium

Energy transfer

Heat exchanger ,electric heating

Temperature control

PID

Temp

control mode

Option:

process temperature control

Jacket temperature control

Process control accuracy

±1°C

Program edit

20 programs,each program has 45 steps(except EX model)

Input and display

7-inch ,10-inch colour touch screen

Closed system

(single liquid)

Closed-loop liquid system without absorbing water vapor at low temperature and

producing oil mist at high temperature .the pressure of liquid will not go up under

high temperature ,and automatically add the heat oil under low temperature

Power

380V50HZ

OPTION:(EX model) SR-10EX SR-20EX SR-38EX SR-60EX SR-95EX

SUNDI -30°C~300°C

Description:

SUNDI -30°C~300°C


-30°C~300°C

Model

SUNDI-V01W
SUNDI-V01
SUNDI-V05W
SUNDI-V05
SUNDI-V10W
SUNDI-V10
SUNDI-V25W
SUNDI-V25
SUNDI-V35W

SUNDI-V50W

Oil temp. range

-30°C~300°C-30°C~300°C-30°C~300°C-30°C~300°C-30°C~300°C-30°C~300°C

controller

PID

Communication

RS485

Temperature control

Option:process temperature control or jacket oil temperature control

Temp.difference

Set or control the temperature difference between jacket oil and raw material process

Tempe. feedback

Jacket oil :PT100Raw material process:PT100

Temp. accuracy

±1°C±1°C±1°C±1°C±1°C±1°C

Heating power

3.5kW5.5kW10kW25kW35kW50kW

Cooling power

300°C4kW6.5kW15kW36kW43kW61kW
200°C3.5kW5kW10kW25kW35kW50kW
100°C3.5kW5kW10kW25kW35kW50kW
20°C3.5kW5kW10kW25kW35kW50kW
-5°C3kW4.3kW10kW23kW31kW42kW
-20°C1.2kW1.9kW2.9kW8kW11kW16kW

Circulation pump

Max35L/min
2Bar
Max50L/min
2Bar
Max50L/min
2Bar
Max110L/min
2Bar
Max110L/min
2Bar
Max110L/min
2Bar

Compressor

CopelandCopelandCopelandCopelandCopelandCopeland

Evaporator

KAORI Plate heat exchanger

Input and display

7-inch colour touch screen, temperature graph display

Security protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,
thermal protection device, liquid low level protection,
high temperature protection and temperature fault protection.

Closed circulation system

The whole system is closed circulation system, low temperature did not absorb
water vapor, high temperature did not produce the oil miss.
although at high temperature, pressure will not go up during the system is
operating. at low temperature, the system will supplementary oil

Refrigerant

R-404AR-404AR404AR404AR404AR404A

Connection size

DN20DN20DN25DN25DN-25DN-32

Water cooled type

Cooling water at 15 degree

1200L/H
1.5Bar~4Bar
1600L/H
1.5Bar~4Bar
2000L/H
1.5Bar~4Bar
3200L/H
1.5Bar~4Bar
4500L/H
1.5Bar~4Bar
6000L/H
1.5Bar~4Bar

Power

AC 230V 50HZ
3500W(max)
AC230V 50HZ
4200W(max)
AC400V50HZ
7800W(max)
AC400V50HZ
11000W(max)
AC400V50HZ
15500W(max)
AC400V50HZ
29000W(max)

Case material

SUS 304SUS 304SUS 304SUS 304SUS 304SUS 304
one host with many reacors ,integrated temperature control systems for 3-20 reactors.
Packaging Detail:standard exported wooden case
Delivery Detail:20-25working days

Related Product for one host with many reacors ,integrated temperature control systems for 3-20 reactors.


Warning: Cannot modify header information - headers already sent by (output started at /home/machineto/machineto.com/sys/db_mysqli.php:1) in /home/machineto/machineto.com/app/ctrl/productCtrl.php on line 208