Boiler flue gas CO2 recovery system (Carbon Dioxide)

Boiler flue gas CO2 recovery systemCarbon dioxide production lineco2 producing and purifyng machineCO2 generator equipmen - details see: https://www.machineto.com/boiler-flue-gas-co2-recovery-system-carbon-dioxide-10029501
Processing:OtherCondition:NewPlace of Origin:Jiangsu China (Mainland)Brand Name:jiexinjixie
Model Number:JX-C02After-sales Service Provided:Engineers available to service machinery overseasStainless steel:metalProcessing Types:Carbonated Beverage
Boiler flue gas CO2 recovery system (Carbon Dioxide)
contact supplier for Boiler flue gas CO2 recovery system (Carbon Dioxide)


CO2 Plant description

CO2 Generating Plant(CBU) is based on combustion of various fossil fuels such as diesel oil, heavy oil, kerosene or natural gas.

Through appropriate combustion, scrubbing, stripping and separation technology

The plants are supplied with a control panel, which ensures continuous trouble-free operation. All instruments installed on the skids are wired to junction boxes prior to shipment and thus reducing installation and commissioning time on site.

CO2 Generating Plant Standard Sizes: 35~1800kg/hr - other sizes available on request.

The plant is based on combustion in the MEA heater unit. By means of washing with soda lye in a flue gas

Scrubber the flue gas is cooled and any sulphur dioxide is removed.

From the flue gas scrubber, the flue gas is led through the absorber by means of an exhauster where the CO2 content of the flue gas is absorbed in a MEA (Monoethanolamine) solution.

The gas residue is exhausted. The CO2 rich MEA solution is preheated in the rich/lean solution heat exchanger before it is pumped to the stripper where by further heating CO2 is released.

The stripped lean MEA solution is led from the stripper through the rich/lean solution heat exchanger and the MEA cooler back to the absorber.

The CO2 gas is cooled in a gas cooler cleaned in a potassium permanganate (PPM) scrubber and led to the CO2 compressor, which compresses the gas in two stages to approx. 16 bar(g).

To allow condensation the CO2 gas is dried in a dehydrator to a dew point of abt. -60°C.

The CO2 is then passed through a carbon filter for removal of odors.

The purified and dried gas is condensed in a multitube heat exchanger at a temperature of about -30°C.

The matching refrigeration plant is equipped with an freon compressor. The refrigeration plant

maintains the correct operating pressure in the CO2 condenser.

The liquid deep-cooled CO2 is led to an insulated CO2 storage tank.

Boiler flue gas CO2 recovery system (Carbon Dioxide)
Packaging Detail:wooden case
Delivery Detail:90-150days

Related Product for Boiler flue gas CO2 recovery system (Carbon Dioxide)


Warning: Cannot modify header information - headers already sent by (output started at /home/machineto/machineto.com/sys/db_mysqli.php:1) in /home/machineto/machineto.com/app/ctrl/productCtrl.php on line 208