220V 1000W PM DC Motor Controller(4Q)

220V 1000W PM DC Motor Controller(4Q), Applicable to permanent-magnet,, separate excitation DC motor, F/R function PLC control - details see: https://www.machineto.com/220v-1000w-pm-dc-motor-controller-4q-10233860
Place of Origin:Shandong China (Mainland)Brand Name:KEYAModel Number:MMT-115/230RT10ALMotor Type:DC Motor
Type:Motor ControllerInput voltage range:115/230VACOutput voltage:0-90VDC/0-110VDC/0-180VDC/0-230VDCPeak currenct:10A
Continous current:5AControl mode:potentiometer/ 0---+/-10VIf F/R function:YesOutline size:115*100*80MM
220V 1000W PM DC Motor Controller(4Q)
contact supplier for 220V 1000W PM DC Motor Controller(4Q)


220V 1000W PM DC Motor Controller(4Q)

MMT-115/230RT10/15ALFour Quadrant Operation

. Summary

MMT-SCR series DC motor controllers are full-wave positive feedback motor controllers and can control motors in It provides four-quadrant operation, which can realize positive and reverse torque in two speed directions.

.Product Features

1. Applicable to permanent-magnet, separate excitation DC motor

2. Large torque for low-speed start-up.

3. The mechanical characteristics of hardness, static error rate of 1%.

4. A wide speed-regulating range (0 - max).

5. A rapid dynamic response process.adjustable

6. Automatic and smooth transition process during acceleration or deceleration.

7. Current setting and current limiting protection (If the preset current value is exceeded, the driver stops output automatically.)

8. Setting functions of and opposite soft start/soft stop time (adjustable)

9. Self lock-up function.

10. Positive rotation and reverse rotation are selectable.

11. Dual closed loop PI adjustment (Current and Voltage)The closed-loop feedback is selectable.

12. The speed control mode and torque control mode are .

13. The inertial gliding stop and braking stop are selectable.

14. The input voltage and output voltage are selectable.

. Main Parameters

1. AC Input Voltage (VAC±10% 50/60HZ) ----------------------------------------115V/230V

2. AC Frequency (Hz) -------------------------------------------------------------------- 50/60

3. Amarture voltage range 115VAC line (VDC) ---------------------------------- 0- ±9 0

4. Amarture voltage range 230VAC line (VDC) ---------------------------------- 0- ±9 0 /0-±180

5. Excitation voltage at 115VAC line (VDC) -------------------------------------- 100/50

6. Excitation voltage at 230 VAC line (VDC) ------------------------------------- 200/100

7. Maximum bearing capacity (% two minutes) --------------------------------- 150

of indoor temperature () ------------------------------------------------------------------- 0-50

9. Speed range in open loop (ratio) -------------------------------------------------- 501

10. Speed range in closed loop (ratio) ---------------------------------------------- 801

11. Regulation of armature feedback loading (% basic speed) ------------- ±1

12. Regulation of closed loop feedback (% rated speed) --------------------- ±1

13. Adjustment of line of alternating current (% basic speed) -------------- ±0.5

14. Current range (A DC) -----------------------------------------------------------------10/15

15. Forward/reverse speed accelerating scope (s) ----------------------------- 0.1- 15

16. Dead zone range (% basic speed) ---------------------------------------------- 0 -±5

17. Range of maximum speed regulation of potentiometer (% basic speed) ------- 55- 110

18. Compensation range in 110VAC line (VDC @ full load) ------------------------------ 0-20

19. IR compensation range in 220VAC (VDC @ full load) --------------------------------- 40

20. Range of forward CL(FCL) and reverse CL(RCL) (% range setting)---------------- 150

21. Volt range changing with the input voltageVDC--------------------------------------- 0-±10/±15

22. Range of voltage with input (% basic speed-------------------------------------------- ±.

23. Ambient HumidityRelative Humidity≤80RH.Below dew point

.Set optional jumper wire

MMT-SCR has the function of customer optional jumper wire, which must be set before implementing control (see the diagram). Letters in bold are set before shipment.

Table 1 Comparison table between location of jumper wire J2 and motor horsepower

motor current at the location of jumper wire J2

motor horsepowerP

90V DC180V DC
10.0A*1.0 (0.75)2.0 1.5
7.53/4 (0.5)1.0
5.01/2 (0.37)1.0 (0.75)
2.51/4 (0.18)1/2 (0.35)
1.71/8 (0.12)1/3 (0.25)

Note: Additional radiator is needed when current is set as 10.0A.

Table 2Relationship between location of BM and J3 and AC input as well as motor voltage

Input voltage of AC lineBM locationJ3 locationMotor voltage
115V115VA9090V
230V230VA180180V
230V230VA9090V

Table 3 Connection mode of excitation (only for shunt motor)

AC line voltage(VAC)Motor Voltage(VDC)(VDC)Excitation connection
11590100F+ F-
1159050F+ L1
230180200F+ F-
230180100F+ L1
220V 1000W PM DC Motor Controller(4Q)
Packaging Detail:carton
Delivery Detail:2days

Related Product for 220V 1000W PM DC Motor Controller(4Q)


Warning: Cannot modify header information - headers already sent by (output started at /home/machineto/machineto.com/sys/db_mysqli.php:1) in /home/machineto/machineto.com/app/ctrl/productCtrl.php on line 208