Stego heater,HGL 046 stego heater,semiconductor fan heaters(stego)

Model HGL046 Industrial Air Conditioners Zhejiang,China(Mainland) Ref 10222822

Price on request

Pricing is provided on request — use the quote form below.

Port
Ningbo/Shanghai
Minimum Order Quantity
1000 Piece/Pieces none
Supply Ability
2000 Piece/Pieces per Week none
Payment Terms
L/C,T/T,Western Union

Request a Quote

Product: Stego heater,HGL 046 stego heater,semiconductor fan heaters(stego)

Attachment optional · PDF, Word, Excel, image · max 10 MB
No file chosen
We usually reply within 12 hours.

Key features

ptc heater, industrial fan heater,electric fan heater,electric heater·stego HGL046 heater·have the CE.ROSH

Specifications

Type Industrial Fan Heater Place of Origin Zhejiang China (Mainland)
Model Number HGL046 Operating Voltage 230 VAC
Mounting Floor Standing Certification CE
Details ptc heater, industrial fan heater,electric fan heater,electric heater · stego HGL046 heater · have the CE.ROSH

Packaging & delivery

Packaging Detailexporting pack or Neutral
Delivery Detail15 Days

Product description

  • Compact Design
  • Clip fixing
  • Long service life
  • Maintenance free
  • Temperature safety cut-out

Compact fan heater prevents formation of condensation. The integrated high performance axial fan provides forced air circulation and so guarantees an even temperature in enclosures. With internal terminal connector.

Heating elementresistance heater
Temperature safety cut-outto protect against overheating in case of fan failure
Heater bodyanodised extruded aluminium profile
Surface temperaturemax. 75°C (400W)
Axial fan, ball bearingAirflow, free flow
AC: 45m³/h (50HZ) or 54m³/h (60Hz)
DC: 54m³/h
service life 50 000h at 25°C (77°F)
Connectioninternal connection terminal 1.5mm² with clamping torque 0.8Nm max.
Connection casingplastic according to UL94 V-0,black
Mountingclip for 35mm DIN rail, EN 50022
Fitting positionvertical
Operating/Storage temperature-45 to +70 °C (-49 to +158 °F)
Protection type/Protection classIP20 / I (earthed)

Note: In the case of 24VDC and 48VDC the fan heater has to be switched via a relay. For this purpose we recommend our electronic relay SM 010 (Art. No. 01000.0-00 and 01001.0-00).

Art. No.Operating voltageHeating capacityLength (L)Weight (approx.)Approvals
04640.0-00230VAC, 50/60Hz250W182mm1.10kgVDE + UL File No. E150057
04641.0-00230VAC, 50/60Hz400W222mm1.40kgVDE + UL File No. E150057
04640.9-00120VAC, 50/60Hz250W182mm1.10kgVDE + UL File No. E150057
04641.9-00120VAC, 50/60Hz400W222mm1.40kgVDE + UL File No. E150057
04640.1-0024VDC250W182mm1.10kg-
04640.2-0048VDC250W182mm1.10kg-
04641.2-0048VDC400W222mm1.40kg-

....

FAQ

What model is this machine?
The model number is HGL046.
What type of machine is it?
It is a Industrial Fan Heater.
What certifications does it have?
Certification: CE.

Related products in Industrial Air Conditioners