hygienic air handling unit

velt,air conditioning units,hrv units,booster,vrf units,evoporative cooling units,slot air grill,rooftap air grill - details see: https://www.machineto.com/hygienic-air-handling-unit-10248408
Place of Origin:Izmir TurkeyBrand Name:AKSALModel Number:AKS- 
hygienic air handling unit
contact supplier for hygienic air handling unit


General

Between 1000 – 110000 m3/h air flow capacity.12 different types and dimensions.They can be dismantled through modular system

Unit Structure

Units are type of modular and can be shipped as dismantle on demand.Assembling of the units is possible as internal through nuts and bolts.It is made use the neoprene tightness gasket on surface of the units’ connection points.It is manufactured using service lids,hinges,clips or door handles.These materials are durable against corrosion.There is observation window,start-stop buton,door switch on service lids and lighting fixture in the units.There are technical information stickers on the device.Units are durable to 25000 pa pressure and are designed as impermeability under this degree.

Carcasses

Special structural aluminium or optional anodized structural aluminium carcass.It is made use carcass plastic corner as size of 40 for device which capacity is between 1.000-15.000 m³/h, size of 50 for device which capacity is too big of 15.000m³/h.Carcasses consist minimium 2 mm gravity structural aluminium

Panels

All panels are made as double-hull sandwich structural.The gravity of internal steel metal is 0,60 mm(standart) and external steel metal gravity is changeable for size of device.In generally surface of panels are manufactured through PVC covered galvanize steel and also electorstatics paint covered is available.For isolation,it is injected 20-25mm polyurethane or made use rock wool as capacity.

Fans

Nicotra marked,models AT and ADH,dynamically balanced,thin wings,with flexible connector are used for making the device.

Electricity Motors

Tri-phase motors(380V-50hz),Mono-phase also usable.Motors are safed IP54 and IP55 class.Optionally can be used as twin cycle.

Drive Control System

V-belt pulley are type of V and certificated by DIN 2211,TS 148

Heat Exchangers

Heating and Cooling exchanger consist of the aluminium lamel parts on copper pipe.Collectors are built through anti-corrosive painted steel pipe.Exchangers are mounted on drays on a free movement basis in device.On the collectors there is nipple for taking aspiration purger.Optionally it can be produced as galvanized steel pipe or stell wing(panel).Cooling exchangers are built expansioned copper pipe or aluminium panel.They include freon distributor for source of freon gas or capillary pipe.Exchanger exist of max.12 atm.hydraulic pressure test.

Vestige-keepers and condensation pans

In the cooling exchangers include PVC or aluminium panelled vestige-keepers as to airflow velocity.1.5 mm galvanize gravity and optionally condensation pans maden stainless steel.

Humidifiers

Hydorus or vaporous type of humidifiers.Air deflectors,water circulation system,seperators, hermetic control device and humidifying pool.Seperator and deflector consist of aluminium structural steel or PVC materials.

Filters

Filters are eligible for standarts of ASHRE.Filters include these types;

*EU-2,EU-3,EU-4 norms are synthetic fibre.

*EU-5,EU-7,EU-9 norms are pack.

*EU-13,EU-14 norms are hepa filters

Optimum air flow velocity,V-type design,standart filters are synthetic fibre and with the assistance of special transportation drays they can mount-demount easily.The other filters are also hermetic and optionally it’s taken perfume-keeper carbon panel filters.

Mixture Unit and Dumpers

Max. 6 m/sn air flow capacity.Dumpers are built as eligible manuel or servo motor commandation.

Exhaust Unit

Manuel or motor command drive control.Include inners and dumpers

Silencer Unit

In consideration of constriction,it hold the distinction of being the other feature.Internal partition of silencer plates,air flow,ventilation type,number of panels are designed according to frequence and intensity of silenced voice and is became 10-20 centimetric plates.Galvanize steel,mineral wool or rock wool.

Heat Recovery Unit

It is built aluminium plate-type or drum-type