Bench Top Ionizing Air Blower E0101
Price on request
Pricing is provided on request — use the quote form below.
- Port
- Shenzhen
- Minimum Order Quantity
- 1 Set/Sets
- Supply Ability
- 10,000 Set/Sets per Month
- Payment Terms
- L/C,T/T,Western Union
Price on request
Pricing is provided on request — use the quote form below.
Something wrong with this listing? Report it
Bench Top Ionizing Air Blower·1.Static Elimination·2.Benchtop typ·3.Adjustable air volume·4.Use with high voltage generator
| Place of Origin | Guangdong China (Mainland) | Model Number | E0101 |
|---|---|---|---|
| feature | static elimination | Details | Bench Top Ionizing Air Blower · 1.Static Elimination · 2.Benchtop typ · 3.Adjustable air volume · 4.Use with high voltage generator |
| Packaging Detail | carton |
|---|---|
| Delivery Detail | 2 weeks |
Bench Top Ionizing Air Blower E0101
Bench Top Ionizing Air Blower E0101is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.
Specification:
| Operating Voltage | 110V/60HZ OR 220V/50HZ |
| Current Consumption | 0.25A OR 0.12A |
| Operating Temperature | -10~50°C |
| Size | 90mm(L)×170mm(W)×260mm(H) |
| Weight | 3.3Kg |
| Air Volume | 45~110CFM |
| Ion Balance | 0V±10V |
| Air Coverage | 40cm×60cm |
Decay test Results:
| Testing Conditions | Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22°C Test Humidity:75%RH | |||
| Distance | 300mm | 600mm | 900mm | |
Decay time | Positive | 1.2s | 2.5s | 3.9s |
| Negative | 1.3s | 2.6s | 4.1s | |
Offset voltage | Positive | 8V | 5V | 4V |
| Negative | -7V | -6V | - | |