3500W IP23/IP55 environmantal protect Industrial electric cabinet air conditioner

Model SAD135-1 Industrial Air Conditioners Jiangsu,China(Mainland) Ref 10222854

Price on request

Pricing is provided on request — use the quote form below.

Port
SHANG HAI
Supply Ability
2000 Piece/Pieces per Month
Payment Terms
T/T

Request a Quote

Product: 3500W IP23/IP55 environmantal protect Industrial electric cabinet air conditioner

Attachment optional · PDF, Word, Excel, image · max 10 MB
No file chosen
We usually reply within 12 hours.

Key features

1.Long service life·2.High stability·3.Competitive price·4.Low energy consumption

Specifications

Condition New Type Cabinet Air Conditioner
Place of Origin Jiangsu China (Mainland) Model Number SAD135-1
Operating Voltage 220VAC Mounting door mounting
Certification CE After-sales Service Provided Engineers available to service machinery overseas
Rated Voltage 220VACd15% 50/60Hz Cooling Working Temperature +20~+55 Degrees Celsius
Heating Working Temperature -40~+15 Degrees Celsius Cooling Capacity 3500W
Refrigerant R134a Weight 68 Kgs
Noise 69dB Color RAL7035
IP Grade IP23/IP55 Dimension(W*H*D) 585*1400*225mm
Details 1.Long service life · 2.High stability · 3.Competitive price · 4.Low energy consumption

Packaging & delivery

Packaging Detail1 PC/Carton with foam
Delivery Detail25 Days After Deposit or L/C

Product description

Door Mounting Industrial Cabinet Air Conditioner

Scope:

1.Widely used in telecommunications,broadcasting,electricity,automation and other industries out-door cabinet,IDC room cooling needs.

2.Applications:electric equipment control box,battery compartment,and telecommunication equipment and other pertinent equipments,enclosed area climate control such as wireless communication cabinet,battery cabinet,industry control cabinet etc.

Features:

1. With compact structure and reasonable design, it includes door mounted, side mounted and top mounted series. The cooling capacity ranges from 400W to 3500W.

3. The protective level of internal and external circulation is IP55, which can protect cabinet to avoid moisture, dust, water and also be installed inside and outside

4. Can run at high ambient environment 55°C.

5. Digital temperature controller and high precision of temperature control.

6. The main components have CE certifications, which can meet EU RoHS requirements

Technique Data Sheet:

Installation Instruction:

1.Don't use the equipment in the environments with more dust, oil moisture, corrosive or harsh air. Among them shall not exceed 55°C ambient temperature, and not lower than 0°C, humidity should not exceed 95%.

2.Use M6*10 screws fix flange on cabinet.

3.Drain cannot stress, after the installation must ensure smooth condensate drain, handling or moving the equipment, do not upside down, tilt and collision.

Installation Picture:

Application:

Related Products:

How to Determine Correct Model of Cabinet cooler

Key Point---Calculating Heat Load for your Enclosure
To determine the correct model for your application, it is first necessary to determine thetotal heat loadto which the control panel is subjected. This total heat load is the combination of two factors — heat dissipated within the enclosure and heat transfer from outside into the enclosure.

Steps of Calculating Btu/hr.:
1. First, determine the approximate watts of heat generated within the enclosure. Watts x 3.41 = Btu/hr.

2. Then, calculate outside heat transfer as follows:
a. Determine the area in square feet exposed to the air, ignoring the top of the cabinet.
b. Determine the temperature differential between maximum surrounding temperature and desired internal temperature. Then, using the Temperature Conversion Table (below), determine the Btu/hr./ft.2for that differential. Multiplying the cabinet surface area times Btu/hr./ft.2provides external heat transfer in Btu/hr.

3. Add internal and external heat loads to get total heat load.

Temperature Conversion Table

Temperature
Differential ° F
Btu/hr/ft.2
51.5
103.3
155.1
207.1
259.1
3011.3
3513.8
4016.2
Example:
Internal heat dissipation: 650 Watts or 2216 Btu/hr.
Cabinet area: 40 ft.2
Maximum outside temperature: 110°F
Desired internal temperature: 95°F
The conversion table (above) shows that a 15°F temperature differential inputs 5.1 Btu/hr./ft.2

40 sq. ft. x 5.1 Btu/hr./ft.2= 204 Btu/hr. external heat load.

Therefore, 204 Btu/hr. external heat load plus 2216 Btu/hr. internal heat load = 2420 Btu/hr. total heat load or Btu/hr. refrigeration required to maintain desired temperature.
In this example, the correct choice is a 2500 Btu/hr. Cabinet Cooler System.

More details,pls contact us!

FAQ

What model is this machine?
The model number is SAD135-1.
What type of machine is it?
It is a Cabinet Air Conditioner.
Is it new or used?
Condition: New.
What voltage does it operate on?
Operating voltage: 220VACd15% 50/60Hz.
How much does it weigh?
Weight: 68 Kgs.
What certifications does it have?
Certification: CE.
What warranty is offered?
Warranty: Engineers available to service machinery overseas.